QFF-560 Quick Feather Float
High-Strength Trowelable Feather Patch
Special features
- Allows for flooring installation after 1 hour
- Levels up to 1" thick
- Very easy to spread
- Can be used over cutback adhesive
- To be used under any flooring
High-Strength Trowelable Feather Patch
Special features
Product Description |
Fast setting concrete mix for filling holes and building ramps over any sound subfloor. Easy to spread, set up very quickly, suitable under wood flooring, ceramic tiles, and resilient floorings. |
Pre-Installation Checklist |
A successful installation requires proper preparation of the subfloor. Read and understand all applicable guidelines and technical data sheets before installation. Follow industry standards and flooring manufacturers' recommendations for subfloor moisture content, design, layout, and application of flooring materials. The backing of all flooring material must be solid, sound, and free of anti-adherents. All slab constructions must meet the specific requirements of the floor covering to be installed. |
Sub Floor Examination |
Moisture content in concrete subfloors must be below 3#/24hr/1000SF using the Calcium Chloride Test or below 75% RH using an in-situ probe per ASTM F1869 and F2170. |
Prior to installation, the subfloor must be checked according to applicable installation guidelines. It must be solid and sound, permanently dry, clean, free of chaps and anti-adherents, and resistant to pressure and tension. The moisture content of all floors must be measured before installation. |
Sub Floor Preparation |
The subfloor's condition will determine which type of mechanical treatment is required (e.g., wire brushing, sanding, grinding, or shot blasting). Dust, paint, curing compounds, sealers, residual adhesives, or other surface contaminants MUST be removed, and a porous surface must be achieved by suitable means. The installer can only determine the extent of subfloor preparation at the site. Clean the surface with an industrial vacuum cleaner and tack the floor with a damp microfiber mop before application. Do not use sweeping compounds unless water-based, as most others contain oil or wax, which will act as an anti-adherent and prevent primers, sealers, leveling compounds, coatings, and/or adhesives from bonding to the concrete. Cracks and gaps must be treated before application of primers, sealers, leveling compounds, coatings, and/or adhesives (see Technical Information #19 @ www.staufusa.com). |
Apply suitable primer or sealer to the subfloor before spreading cement or gypsum-based leveling compounds to increase the bond. |
Mixing of Components |
Fill a bucket with the correct amount of cold water. Wear a proper dust mask when using powdered products in enclosed areas. While stirring, add powder to the water and continue stirring until an even mixture is formed. Use an electric mixer with 600 to 800 RPM. Stir for two more minutes, wait one minute, and stir again for one minute. |
Installation Procedure |
Spread the floor patch within approx. 15 min. and protect it from direct sunlight and draft during drying. |
Limitations |
When using other than STAUF products in conjunction with STAUF primers, sealers, leveling compounds, or adhesives, STAUF denies any and all responsibility for any ensuing problems and/or damages without prior written authorization from STAUF. |
In case of an accident, injury, spill, or exposure, see SDS for information. Consult the Technical Data Sheet at www.staufusa.com for updated information. |
The foregoing representations are based on the results of our most current product and material testing within a controlled environment and are of a non-obligatory advisory nature only. As such, they do not constitute an express or implied warranty of any kind including the Warranty of Merchantability and/or Fitness for a Particular Purpose. Because we have no control over the actual quality of workmanship, materials used, and worksite conditions, STAUF USA LLC will in no event be liable for any incidental and/or consequential damages. Therefore, we strongly recommend that prior on-site testing be conducted to refer to and study the suitability of the product for the intended purpose. With the release of this Technical Information Sheet, all its prior versions become invalid. For warranty and warranty disclaimer information please see our Limited Lifetime Warranty @ www.staufusa.com |
|
|
||||||||||||||||||||||||||||||||||
Revision: 2022-04-18 14:08:11 |